Axial force measurement for tensile test machines, suspended weighing and automated test fixtures. Start with the load case, then match the thread and signal chain.

5 N–20 t FAMILY ENQUIRY SCOPEConfigure TLC-SBM & request quote →
Rigid off-axis mount compared with self-aligning rod-end assembly, schematic not to scale
CONFIGURATION SCHEMATIC · NOT A DIMENSIONAL DRAWING
MATERIAL / CONSTRUCTION

17-4PH stainless or alloy steel options

MECHANICAL INTERFACE

Metric M6–M36 or 1/4-28 to 1-1/4-12 UNF, by capacity

SIGNAL CHAIN

2.0 / 3.0 mV/V; conditioned output options

Low-force enquiry points: 5, 10, 20, 50, 100, 200 and 500 N. Industrial enquiry scope: 100 kgf–20 metric tonne-force; 200–40,000 lbf configurations require separate selection, not a point-for-point conversion. Metric M6–M36 and 1/4-28 through 1-1/4-12 UNF are model-dependent; nonstandard threads require a quantity and lead-time review.

Ranges and options cover multiple configurations. A quotation confirms the capacity, material, thread, sealing, calibration and output of the selected unit.

CONFIGURATION AND DOCUMENT REVIEW

Compare the load path and signal before the drawing review

Enquiry references — final nominal rating and dimensions require approved model documentation
Configuration referenceForce / use envelopeSignal requestMechanical and evidence checksEnquiry
TLC-SBM-2MV

2.0 mV/V S-beam enquiry

5N–20 metric tf across configurations2.0 mV/V bridge / 4–20 mA / 0–10 V / RS485 ModbusMetric M6–M36, model dependent

Confirm capacity-specific dimensions, thread depth, bridge resistance and calibration direction.

Dimensions, accuracy and model datasheet: confirm on the approved configuration.
Request TLC-SBM-2MV review →
TLC-SBM-3MV

3.0 mV/V S-beam enquiry

5N–20 metric tf across configurations3.0 mV/V bridgeUNF 1/4-28 through 1-1/4-12, model dependent

Match sensitivity, excitation, wiring and complete thread callout before replacing a sensor.

Dimensions, accuracy and model datasheet: confirm on the approved configuration.
Request TLC-SBM-3MV review →
TLC-SBM-UTM

UTM / TEDS S-beam review

Application-specific force range2.0 mV/V bridge / 3.0 mV/V bridge / IEEE 1451.4 TEDS requestFixture height / connector / thread review

Request actual overload-stop travel/rating, connector pinout, TEDS support and separate directional calibration.

Dimensions, accuracy and model datasheet: confirm on the approved configuration.
Request TLC-SBM-UTM review →

BRIDGE SENSITIVITY / ELECTRICAL EXAMPLE

2.0 or 3.0 mV/V changes the amplifier span

20 mV ideal full-scale bridge output

Output sensitivity × excitation gives the ideal full-scale signal. The excitation here is an example, not the allowed supply rating of a selected sensor. Check bridge resistance, zero balance, wiring and amplifier range. A gain set for 3.0 mV/V will not automatically scale a 2.0 mV/V replacement correctly.

Request this bridge sensitivity →

A similar diameter is not an interchangeable thread

Thread geometry examples, not a capacity-to-thread availability table
Callout exampleNominal diameterPitchDrawing check
M6 × 16 mm1 mmConfirm gender, tolerance, usable engagement depth, jam-nut clearance and installed height.
M12 × 1.7512 mm1.75 mmConfirm gender, tolerance, usable engagement depth, jam-nut clearance and installed height.
1/4-28 UNF6.35 mm25.4 / 28 ≈ 0.907 mmConfirm gender, tolerance, usable engagement depth, jam-nut clearance and installed height.
1/2-20 UNF12.7 mm25.4 / 20 = 1.27 mmConfirm gender, tolerance, usable engagement depth, jam-nut clearance and installed height.

Thread examples explain why near-matching diameters cannot be substituted. Confirm the actual capacity-specific drawing; special pitches and larger interfaces require a separate manufacturing review.

BEFORE YOU SELECT CAPACITY

Keep side loads out of the measuring axis

  1. Specify tension, compression or calibrated bidirectional operation.
  2. Confirm thread diameter, pitch, engagement length and bearing centre distance.
  3. Select rated capacity above the actual peak load; account for acceleration and overload events.
  4. Request model-specific sealing, temperature, creep, non-linearity and calibration data.

DESIGNED AROUND THE INSTALLATION

Where this geometry fits

  • Universal tensile testing machines
  • Suspended hopper & tank scales
  • Belt take-up and force-controlled fixtures
Discuss your load case →

CONFIGURE THE COMPLETE ASSEMBLY

Match the connection.
Protect the measurement.

Spherical rod-end bearings accommodate permitted angular movement. Check load ratings, thread engagement, jam-nut torque and the sensor mounting instructions. They do not make every off-axis installation acceptable.

  • Matched pair of spherical rod-end bearings + jam nuts
  • Pair of forged eye bolts / clevis yoke forks
Include accessories in my RFQ →

What to verify on the selected unit

Request a model drawing and pinout, the rated force and overload limits, calibration direction and test points, operating temperature, and model-specific environmental protection.

For digital configurations, confirm IODD / IO-Link implementation or the RS485 protocol and register map. For lifting or protective functions, establish the required certification and independent safety assessment before procurement.

Accessory prices, availability and lead time are confirmed with the configured quote.

WEB-ROLLER EQUATION REFERENCE

F = 2 × T × sin(θ / 2)

This equal-tension, frictionless web-roller relation uses travel-direction deflection θ. It is not a lifting rating or an installed wire-rope clamp calibration model. Roller weight, dynamic loads and support distribution are separate.

Review geometry, units and measurement limits →

ENGINEERING QUESTIONS / TLC-SBM

Can one sensor measure tension and compression?

Specify bidirectional calibration, the required force range in each direction, and the zero and span behaviour. A tension-only calibration does not establish compression performance.

Will a UNF bearing fit a metric sensor?

No. Diameter and pitch must both match. Send the complete thread callout, mounting drawing and required engagement length for review.

Can you quote an existing-brand replacement?

Send the exact part number, drawing and calibration data. We compare dimensions, mechanical ratings and electrical interfaces before proposing a configuration. See the replacement checklist.

REPORT SCOPE / FIELD CHECKLIST

Know what a supplied report must contain

Preview the information to request before ordering. This is a blank field checklist, not an issued calibration certificate, proof-test result or laboratory accreditation.

Download open checklist PDF →

Report fields to request

No test values, certificate number, issuer seal or accreditation status is represented here.

Factory force record

  • Sensor model / serial and direction
  • Reference instrument and traceability
  • Actual applied loads and readings
  • Loading / unloading, zero return and repeatability
  • Environmental conditions, date and sign-off

Accredited calibration report

  • Issuing laboratory identity
  • Accreditation body, certificate and current scope
  • Force range, direction, method and uncertainty
  • Instrument identification and calibration results
  • Any limitations and authorised report signatory

Proof-load test record

  • Device model, serial and rated working load
  • Test method, applied load and duration
  • Reference loading equipment and traceability
  • Inspection / acceptance criteria and actual outcome
  • Breaking-load evidence separately identified

CONFIGURATION / INTERFACE / DELIVERY

Send an engineering RFQ with the details intact

Choose the force path, signal and matching accessories. Include the destination so the quotation can confirm the product, calibration, freight and requested delivery term together.

[email protected]

Open engineering notes are available in the downloads centre. Approved model STEP, IODD and real calibration reports are supplied against the selected configuration. Price, availability, lead time and warranty terms are confirmed in the formal quote.

1 / Contact
2 / Sensor geometry and configuration
6 / Hardware & calibration requests

Options are quotation requests. The final assembly rating and documentation scope require model-specific confirmation.

8 / Quantity & delivery country

TLC Tensile Metrology uses these details to respond to your enquiry. Privacy policy.