Bridge amplifier
Confirm mV/V sensitivity, excitation, bridge resistance, four- or six-wire connection, zero balance and cable length.
TLC ENGINEERING / SPECIFY WITH CONTEXT
Match a bridge amplifier, PLC transmitter, wireless readout or closed-loop PID controller to the transducer and machine interface.
Confirm mV/V sensitivity, excitation, bridge resistance, four- or six-wire connection, zero balance and cable length.
For 4–20 mA / 0–10 V, agree the force scaling, supply and fault handling. For IO-Link, confirm device data and master compatibility; for RS485, confirm baud rate, address and registers.
Define peak-hold behaviour, sampling rate, resolution, battery life, radio region and the response to loss of communication.
CONFIGURATION AND DOCUMENT REVIEW
| Configuration reference | Force / use envelope | Signal request | Mechanical and evidence checks | Enquiry |
|---|---|---|---|---|
| TLC-CTL-PID Closed-loop PID controller review | Sensor and drive dependent | Closed-loop PID controller | Panel / rail mounting and drive interface Match sensor input, feedback scaling,0–10V/PWM output, line speed and tuning. Dimensions, accuracy and model datasheet: confirm on the approved configuration. | Request TLC-CTL-PID review → |
| TLC-CTL-M12 M12 IO-Link bridge transmitter | Bridge excitation and input dependent | M12 IO-Link | M12 pinout / supply / cable routing Request IODD, bridge supply, resolution, process data and actual cycle-time limits. Dimensions, accuracy and model datasheet: confirm on the approved configuration. | Request TLC-CTL-M12 review → |
| TLC-CTL-DIN DIN-rail bridge transmitter | Bridge input dependent | 4–20 mA / 0–10 V / RS485 Modbus | Rail / shielding / PLC input Confirm bridge sensitivity, gain range, address/register map and fault current. Dimensions, accuracy and model datasheet: confirm on the approved configuration. | Request TLC-CTL-DIN review → |
| TLC-CTL-WLS Wireless peak-hold readout | Paired radio system dependent | Wireless handheld kit | Readout, receiver and transmitter protocol Confirm compatible transmitter, peak capture rate, communication-loss response and battery. Dimensions, accuracy and model datasheet: confirm on the approved configuration. | Request TLC-CTL-WLS review → |
FMS CMGZ309 is a controller reference; FMS RMGZ is a force-sensor reference. Match the complete input and drive interface rather than treating the two as interchangeable products.
The transducer measures roller force. The controller translates a calibrated measurement into a command for the brake, magnetic-powder clutch or servo drive. Roller inertia, material elasticity, line speed and control delay all affect tuning.
Display resolution is not measurement accuracy. A 0.01 N display increment is meaningful only for a system with a suitable range, noise floor and verified calibration.
Specify the sensor + controller chain →Download the force-selection guide and editable interface worksheet.
Calibration and proof-load scope →Identify which report and accreditation scope the application requires.
Compare enquiry configurations →Filter the geometry, force envelope and signal before requesting a model.